Availability: | |
---|---|
Quantity: | |
Magnetic drive circulation pump is a full-sealed pump, for motor connecting shaft and impeller are separately equipped with magnetic materials, they attract each other and coupled. Its unnecessary to fit with traditional shaft seal. The rotation torsion of motor drives impeller to rotate through the attraction between driving magnet and driven magnet. The shortcoming of present customary magnetic drive pump is that rotation is absolutely prohibited under the condition of lacking liquid, otherwise, the machine will be destroyed, resulted in unnecessary troubles for customer. We adopt special ceramics as shaft bearing, characterizing strong resistance for abrasion and corrosion.
Features
Magnetic drive circulation pump is generally designed for no shaft seal, completely avoids defects of pollution after corrosion caused by liquid leakage, which exists in traditional mechanical shaft seal pump, it is the optimum liquid transport pump on the industrial equipments.
Operated data
Magnetic drive circulation pump
Flow:2.8~380L/min
Head:0.8~22m
Motor:6~2200W
Phase: 1 or 3
Magnetic drive circulation pump is a full-sealed pump, for motor connecting shaft and impeller are separately equipped with magnetic materials, they attract each other and coupled. Its unnecessary to fit with traditional shaft seal. The rotation torsion of motor drives impeller to rotate through the attraction between driving magnet and driven magnet. The shortcoming of present customary magnetic drive pump is that rotation is absolutely prohibited under the condition of lacking liquid, otherwise, the machine will be destroyed, resulted in unnecessary troubles for customer. We adopt special ceramics as shaft bearing, characterizing strong resistance for abrasion and corrosion.
Features
Magnetic drive circulation pump is generally designed for no shaft seal, completely avoids defects of pollution after corrosion caused by liquid leakage, which exists in traditional mechanical shaft seal pump, it is the optimum liquid transport pump on the industrial equipments.
Operated data
Magnetic drive circulation pump
Flow:2.8~380L/min
Head:0.8~22m
Motor:6~2200W
Phase: 1 or 3
Model | Tube Connection | Thread Connection | Max Flow (L/min) | Max Head (m) | Standard | S.G | Motor | ||||
Inlet (mm) | Outlet (mm) | Inlet (inch) | Outlet (mm) | 50Hz/60Hz | 50Hz/60Hz | Flow (L/min) 50Hz/60Hz | Head(m) 50Hz/60Hz | Power (w) | Phase | ||
MP-6R | 14 | 14 | - | - | 8/9 | 1/1.4 | 2.8/5 | 0.8 | <1.2 | 3 | 1 |
MP-6RZ | 14 | 14 | - | - | 5.5/6 | 2.1/2.7 | 3.2/4.5 | 0.8 | <1.1 | 3 | 1 |
MP-10R | 14 | 14 | - | - | 11/12 | 1.5/2.1 | 5/8 | 1 | <1.1 | 6 | 1 |
MP-10RN | 14 | 14 | - | - | 11/12 | 1.5/2.1 | 5/8 | 1 | <1.1 | 6 | 1 |
MP-15R | 16 | 16 | - | - | 16/19 | 2.7/3.4 | 8/12 | 1.5 | <1.3 | 10 | 1 |
MP-15RN | 16 | 16 | - | - | 16/19 | 2.7/3.4 | 8/12 | 1.5 | <1.3 | 10 | 1 |
MP-15RM | - | - | 3/4 | 13 | 16/19 | 2.4/3.4 | 8/12 | 1.5 | <1.3 | 10 | 1 |
MP-20R | 18 | 18 | - | - | 27/32 | 3.1/4.3 | 17/22 | 2 | <1.2 | 20 | 1 |
MP-20RM | - | - | 3/4 | 16 | 27/32 | 3.1/4.3 | 17/22 | 2 | <1.2 | 20 | 1 |
MP-20RX | 26 | 26 | - | - | 46/52 | 1.8/2.5 | 30/40 | 1 | <1.3 | 20 | 1 |
MP-20RXM | - | - | 1 | 20 | 46/52 | 1.8/2.5 | 30/40 | 1 | <1.3 | 20 | 1 |
MP-2RZ | 18 | 18 | - | - | 10/11 | 4.6/6.9 | 7/10 | 4 | <1.1 | 20 | 1 |
MP-20RZM | - | - | 3/4 | 13 | 10/11 | 4.6/6.9 | 7/10 | 4 | <1.1 | 20 | 1 |
MP-30R | 20 | 20 | - | - | 33/38 | 3.8/5.4 | 16/25 | 2.5 | <1.3 | 45 | 1 |
MP-30RM | - | - | 3/4 | 16 | 33/38 | 3.8/5.4 | 16/25 | 2.5 | <1.3 | 45 | 1 |
MP-30RX | 26 | 26 | - | - | 62/72 | 2.9/4.1 | 32/46 | 2 | <1.1 | 45 | 1 |
MP-30RXM | - | - | 1 | 20 | 62/72 | 2.9/4.1 | 32/46 | 2 | <1.1 | 45 | 1 |
MP-30RZ | 18 | 18 | - | - | 15/17 | 8/11 | 10/14 | 6 | <1.1 | 45 | 1 |
MP-30RZM | - | - | 3/4 | 13 | 15/17 | 8/11 | 10/14 | 6 | <1.1 | 45 | 1 |
MP-40R | 20 | 20 | - | - | 45/52 | 4.6/6.5 | 22/34 | 4 | <1.1 | 65 | 1 |
MP-40RM | - | - | 3/4 | 16 | 45/52 | 4.6/6.5 | 22/34 | 4 | <1.1 | 65 | 1 |
MP-40RX | 26 | 26 | - | - | 75/85 | 3.3/4.7 | 47/65 | 2 | <1.1 | 65 | 1 |
MP-40RXM | - | - | 1 | 20 | 75/85 | 3.3/4.7 | 47/65 | 2 | <1.1 | 65 | 1 |
MP-55R | 26 | 26 | - | - | 60/70 | 5.6/8.2 | 30/45 | 4 | <1.2 | 90 | 1or3 |
MP-55RM | - | - | 1 | 20 | 60/70 | 5.6/8.2 | 30/45 | 4 | <1.2 | 90 | 1or3 |
MP-55RZ | 26 | 26 | - | - | 25/28 | 10/14 | 15/22 | 8 | <1.1 | 90 | 1or3 |
MP-55RZM | - | - | 1 | 20 | 25/28 | 10/14 | 15/22 | 8 | <1.1 | 90 | 1or3 |
MP-70R | 26 | 26 | - | - | 86/97 | 6.7/9.7 | 50/72 | 4 | <1.1 | 150/180 | 1or3 |
MP-70RM | - | - | 1 | 20 | 86/97 | 6.7/9.7 | 50/72 | 4 | <1.1 | 150/180 | 1or3 |
MP-100R | 26 | 26 | - | - | 120/130 | 8.6/11.6 | 60/70 | 7/9 | <1.3 | 250/265 | 1or3 |
MP-100RM | - | - | 1 | 20 | 120/130 | 8.6/11.6 | 60/70 | 7/9 | <1.3 | 250/265 | 1or3 |
MP-100RX | - | - | 1 1/4 | 32 | 170 | 9.0 | 100 | 5.0 | <1.3 | 250 | 1or3 |
MP-120R | - | - | 1 1/2 | 36 | 220 | 10.5 | 140 | 6.0 | <1.3 | 370 | 1or3 |
MP-120RT | - | - | 2 1/4 | 48 | 220 | 10.5 | 140 | 6.0 | <1.3 | 370 | 1or3 |
MPH-400CV5-D | - | - | 1 1/2 | 36 | 260 | 12.5 | 150 | 8.5 | <1.3 | 370 | 3 |
MPH-401CV5-D | - | - | 1 1/2 | 36 | 330 | 18 | 200 | 12 | <1.3 | 750 | 3 |
MPH-422CV5-D | - | - | 2 | 1 1/2 | 300 | 21 | 200 | 18.5 | <1.3 | 1500 | 1or3 |
MPH-423CV5-D | - | - | 2 | 1 1/2 | 360 | 22 | 300 | 20.5 | <1.3 | 2200 | 1or3 |
Model | Tube Connection | Thread Connection | Max Flow (L/min) | Max Head (m) | Standard | S.G | Motor | ||||
Inlet (mm) | Outlet (mm) | Inlet (inch) | Outlet (mm) | 50Hz/60Hz | 50Hz/60Hz | Flow (L/min) 50Hz/60Hz | Head(m) 50Hz/60Hz | Power (w) | Phase | ||
MP-6R | 14 | 14 | - | - | 8/9 | 1/1.4 | 2.8/5 | 0.8 | <1.2 | 3 | 1 |
MP-6RZ | 14 | 14 | - | - | 5.5/6 | 2.1/2.7 | 3.2/4.5 | 0.8 | <1.1 | 3 | 1 |
MP-10R | 14 | 14 | - | - | 11/12 | 1.5/2.1 | 5/8 | 1 | <1.1 | 6 | 1 |
MP-10RN | 14 | 14 | - | - | 11/12 | 1.5/2.1 | 5/8 | 1 | <1.1 | 6 | 1 |
MP-15R | 16 | 16 | - | - | 16/19 | 2.7/3.4 | 8/12 | 1.5 | <1.3 | 10 | 1 |
MP-15RN | 16 | 16 | - | - | 16/19 | 2.7/3.4 | 8/12 | 1.5 | <1.3 | 10 | 1 |
MP-15RM | - | - | 3/4 | 13 | 16/19 | 2.4/3.4 | 8/12 | 1.5 | <1.3 | 10 | 1 |
MP-20R | 18 | 18 | - | - | 27/32 | 3.1/4.3 | 17/22 | 2 | <1.2 | 20 | 1 |
MP-20RM | - | - | 3/4 | 16 | 27/32 | 3.1/4.3 | 17/22 | 2 | <1.2 | 20 | 1 |
MP-20RX | 26 | 26 | - | - | 46/52 | 1.8/2.5 | 30/40 | 1 | <1.3 | 20 | 1 |
MP-20RXM | - | - | 1 | 20 | 46/52 | 1.8/2.5 | 30/40 | 1 | <1.3 | 20 | 1 |
MP-2RZ | 18 | 18 | - | - | 10/11 | 4.6/6.9 | 7/10 | 4 | <1.1 | 20 | 1 |
MP-20RZM | - | - | 3/4 | 13 | 10/11 | 4.6/6.9 | 7/10 | 4 | <1.1 | 20 | 1 |
MP-30R | 20 | 20 | - | - | 33/38 | 3.8/5.4 | 16/25 | 2.5 | <1.3 | 45 | 1 |
MP-30RM | - | - | 3/4 | 16 | 33/38 | 3.8/5.4 | 16/25 | 2.5 | <1.3 | 45 | 1 |
MP-30RX | 26 | 26 | - | - | 62/72 | 2.9/4.1 | 32/46 | 2 | <1.1 | 45 | 1 |
MP-30RXM | - | - | 1 | 20 | 62/72 | 2.9/4.1 | 32/46 | 2 | <1.1 | 45 | 1 |
MP-30RZ | 18 | 18 | - | - | 15/17 | 8/11 | 10/14 | 6 | <1.1 | 45 | 1 |
MP-30RZM | - | - | 3/4 | 13 | 15/17 | 8/11 | 10/14 | 6 | <1.1 | 45 | 1 |
MP-40R | 20 | 20 | - | - | 45/52 | 4.6/6.5 | 22/34 | 4 | <1.1 | 65 | 1 |
MP-40RM | - | - | 3/4 | 16 | 45/52 | 4.6/6.5 | 22/34 | 4 | <1.1 | 65 | 1 |
MP-40RX | 26 | 26 | - | - | 75/85 | 3.3/4.7 | 47/65 | 2 | <1.1 | 65 | 1 |
MP-40RXM | - | - | 1 | 20 | 75/85 | 3.3/4.7 | 47/65 | 2 | <1.1 | 65 | 1 |
MP-55R | 26 | 26 | - | - | 60/70 | 5.6/8.2 | 30/45 | 4 | <1.2 | 90 | 1or3 |
MP-55RM | - | - | 1 | 20 | 60/70 | 5.6/8.2 | 30/45 | 4 | <1.2 | 90 | 1or3 |
MP-55RZ | 26 | 26 | - | - | 25/28 | 10/14 | 15/22 | 8 | <1.1 | 90 | 1or3 |
MP-55RZM | - | - | 1 | 20 | 25/28 | 10/14 | 15/22 | 8 | <1.1 | 90 | 1or3 |
MP-70R | 26 | 26 | - | - | 86/97 | 6.7/9.7 | 50/72 | 4 | <1.1 | 150/180 | 1or3 |
MP-70RM | - | - | 1 | 20 | 86/97 | 6.7/9.7 | 50/72 | 4 | <1.1 | 150/180 | 1or3 |
MP-100R | 26 | 26 | - | - | 120/130 | 8.6/11.6 | 60/70 | 7/9 | <1.3 | 250/265 | 1or3 |
MP-100RM | - | - | 1 | 20 | 120/130 | 8.6/11.6 | 60/70 | 7/9 | <1.3 | 250/265 | 1or3 |
MP-100RX | - | - | 1 1/4 | 32 | 170 | 9.0 | 100 | 5.0 | <1.3 | 250 | 1or3 |
MP-120R | - | - | 1 1/2 | 36 | 220 | 10.5 | 140 | 6.0 | <1.3 | 370 | 1or3 |
MP-120RT | - | - | 2 1/4 | 48 | 220 | 10.5 | 140 | 6.0 | <1.3 | 370 | 1or3 |
MPH-400CV5-D | - | - | 1 1/2 | 36 | 260 | 12.5 | 150 | 8.5 | <1.3 | 370 | 3 |
MPH-401CV5-D | - | - | 1 1/2 | 36 | 330 | 18 | 200 | 12 | <1.3 | 750 | 3 |
MPH-422CV5-D | - | - | 2 | 1 1/2 | 300 | 21 | 200 | 18.5 | <1.3 | 1500 | 1or3 |
MPH-423CV5-D | - | - | 2 | 1 1/2 | 360 | 22 | 300 | 20.5 | <1.3 | 2200 | 1or3 |
During the daily use of the self-priming pump, there will be some more common problems. For example, the self-priming pump's non-pumping problem will be caused by many different reasons, so how do we deal with these problems is the key. The reasons why the self-priming pump does not pump water include the following aspects.
The hot water submersible pump is used for hot spring bathing, and can also be used for extracting groundwater from deep wells, and can also be used for water lifting projects such as rivers, reservoirs, and canals. It is mainly used for farmland irrigation and human and animal water in high mountain areas. It can also be used for central air conditioning cooling, heat pump units, cold pump units, cities, factories, railways, mines, and construction site drainage. The general flow rate can reach 5~650m³/h, and the head can reach 10-550 meters.
Diaphragm pump is a new type of conveying machinery that can convey various corrosive liquids, liquids with particles, high viscosity, volatile, flammable, and highly toxic liquids. Diaphragm pump has four materials: plastic, aluminum alloy, cast iron, stainless steel.